Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Laboratory Medicine ; (12): 267-273, 2020.
Article in Chinese | WPRIM | ID: wpr-871890

ABSTRACT

Objective:To evaluate the performance of aldosterone testing in China through the External Quality Assessment (EQA) and improve the testing quality of aldosterone.Methods:Two kinds of EQA program for aldosterone were carried out in China, one of which is Routine EQA and the other is Trueness verification scheme. Lyophilized sera with 5 concentration levels were used as quality control of Routine EQA. The results were grouped according to the instrument. Target values and the coefficient of variation ( CV) were calculated in each group. Trueness verification scheme was verified by using frozen human sera of 3 concentration levels determined by the reference method, and the bias of each instrument group from the target value was calculated. Results:272 laboratories submitted the testing results, and 91.6% of laboratories used chemiluminescence method. The maximum CV was obtained by radioimmunoassay and liquid chromatography mass spectrometry, and the robust CVs were 14.6%-33.4% and 43.5%-53.9%, respectively. For chemiluminescence methods, the robust group CV was less than 10%. The results of the Trueness verification scheme showed that liquid chromatography mass spectrometry method was the most accurate method, with biases of -7.9%, 8.9% and -0.7% for the three quality controls. Diasorin system had the more accurate results deviated from the target by 58.7%, 7.9% and -2.1%, respectively. The results of other chemiluminescence methods were negatively correlated with the sample concentration, and one of them with a bias of 479%. Conclusions:The accuracy and comparability of aldosterone among laboratories in China are not satisfactory. Reagent manufacturers and laboratories should pay more attention to EQA, with the aldosterone results traceable to SI unit, and improve the test quality of aldosterone.

2.
Chinese Journal of Laboratory Medicine ; (12): 545-551, 2019.
Article in Chinese | WPRIM | ID: wpr-756465

ABSTRACT

Objective Accurate measurement of aldosterone is critical in the diagnosis of primary aldosteronism. We compared the harmonization of three assays including isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) and two chemiluminescence immunoassays (CLIAs:system A and system B) for the aldosterone measurement. Methods A total of 45 plasma samples, 4 quality control materials, 5 lyophilized bovine serums, and 3 fresh frozen human serum pools were measured by three assays respectively. Based on CLSI EP15-A3 rule, the precision was assessed by coefficient of variance. Deming regression and Bland&Altman plots was performed for method comparison, and correlation coefficient was calculated for concordance (CCC). Results All three methods met the performance criteria based on desirable biological variation for precision (<7.35%). System A showed a relevantly good correlation and comparability with ID-LC/MS/MS (R2=0.985, CCC=0.967), while System B showed relevantly bad correlations and comparability with both System A (R2=0.538, CCC=0.605) and ID-LC/MS/MS (R2=0.547, CCC=0.528).. However, the average relevant bias of two CLIAs exceeded the bias requirement derived from biological variation (18.60%). Conclusion Significant differences were found in the measurement of plasma aldosterone using ID-LC-MS/MS and two CLIAs, which urges the establishment of traceability hierarchy and improvement of reagents' specificity for standardization of aldosterone measurement in clinical settings.

3.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 760-763, 2019.
Article in Chinese | WPRIM | ID: wpr-754198

ABSTRACT

The drug cues of multi-sensory have higher reliability and ecological validity,and play a key role in the substance and behavioral addiction. However,the comprehensive discussion on the relation-ship of addiction and the disorder of emotional audiovisual integration was very limited so far. Reviewing re-cent studies on multi-sensory integration of substance and behavioral addictions,it had been found that both two addiction groups had disorders of audiovisual integration,especially the negative emotion. Neuroimaging studies found that the abnormal activation on prefrontal cortical during emotional audiovisual integration com-monly tended to live in substance and behavioral addictions,suggesting that the disorder of emotional audiovi-sual integration for addictions might be related to the weakening of cognitive control. Further improvements of the neural mechanism of emotional audiovisual integration disorder of addictions,as well as the more ecologi-cally predictive indicators and clinical diagnosis criteria are needed.

4.
International Journal of Laboratory Medicine ; (12): 2172-2174, 2015.
Article in Chinese | WPRIM | ID: wpr-477109

ABSTRACT

Objective To study the related factors of no or weak immune response after inoculation of hepatitis B vaccine .Meth‐ods 120casesofadultreceivedinoculationofhepatitisBvaccineinourhospitalwereenrolled,including60casesofnoweakre‐sponse and 60 cases of normal response ,they were divided into non response group and response group .Related factors of no or weakimmuneresponsewereanalyzed.Results (1)singlefactoranalysis:Therewerestatisticalsignificanceofage,gender,BMI, smoking history ,HBV potential infection ,CD4+ T cells and CD8+ T cell content ,IFN‐γand IL‐2 content between two groups ;(2) logistic regression analysis :old age ,male ,smoking history ,high values of BMI ,HPV latent infection ,low content of CD4+ T cells and IFN‐γand IL‐2 ,high content of CD8+ cells were risk factors of no or weak immune response after inoculation of hepatitis B vaccine .Conclusion No or weak immune response after inoculation of hepatitis B vaccine is affected by gender ,age ,smoking ,obesi‐ty ,potential infection of HPV and immune function ,and necessary measure should be taken .

5.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 151-152, 2002.
Article in Chinese | WPRIM | ID: wpr-980446
SELECTION OF CITATIONS
SEARCH DETAIL